Precautions for using float level gauge?


Release time:

2022-11-04

This float level gauge is a liquid level measuring instrument designed according to Archimedes's law. In fact, the product can now be used to measure liquid level, boundary level and density. It is specially used to measure the liquid level in the pressure vessel and consists of meter head, torque tube assembly and inner and outer floats. The following is a note for everyone to use the float level gauge?

This float level gauge is a liquid level measuring instrument designed according to Archimedes's law. In fact, the product can now be used to measure liquid level, boundary level and density. It is specially used to measure the liquid level in the pressure vessel and consists of meter head, torque tube assembly and inner and outer floats. The following is a note for everyone to use the float level gauge?

The float level gauge can be installed vertically to work normally. In addition, the float level gauge has been debugged according to the technical conditions provided by the user when leaving the factory, and generally does not need to be adjusted by the user. If the actual measured media density does not match the provided media density, calibration is required based on the actual density. In addition to doing these, you need to pay attention when installing the float level gauge, check whether the mounting flange surface is in a horizontal position with the container, and then install the gasket for correct installation. If the media page fluctuates greatly, install an anti-wave tube to ensure accuracy. Or check the straightness of the upper and lower flanges of the container before installation to ensure that the float level gauge is installed vertically. At this time, after the float level gauge is installed vertically, when the instrument display is not at zero point, zero point migration can be carried out according to the product operation instructions. After zero setting, the indicator mechanism is firmly fixed outside the measuring magnet cavity by tightening the screw.

Before using the buoy level gauge, check whether the level gauge is within the inspection period, otherwise it shall be verified as unqualified and replaced in time. The wiring of the product shall be operated strictly in accordance with the operating instructions, and shall not be short-circuited or wrong. The connection between the sensor and the explosion-proof junction box shall be tight, and there shall be no rain leakage. The sensor shall be installed horizontally and the operating length shall meet the technical requirements of the enterprise. Of course, it is also very important to carry out product appearance quality inspection and regular data verification after 6 months to 1 year of operation. It is also necessary to regularly check whether the magnetic induction switch element of the sensor fails due to aging, not less than once a month. The verification cycle is 1 year. Regularly check whether the float level gauge is bent by external force to avoid stuck ball failure; At the same time, it is necessary to check the float level gauge to protect the working casing from water leakage. Here is a regular manufacturer, want to order the product friends may wish to come here to choose it. Believe that will not let you down. The price here is reasonable and the quality is guaranteed. Moreover, there are many types of products, and there is always one suitable for you. Welcome to buy. The company has successfully developed on-site level gauges, level transmitters, level switches, pressure/differential pressure transmitters, flow meters, and boiler flame television monitoring devices.

After the introduction of the above contents, we have also understood the matters needing attention in using the float level gauge. Other knowledge points will continue to be updated in the next period. If you have time, please remember to come and watch. There are customer service personnel to receive you 24 hours a day.








Dalian Petrochemical to Wuhan Hyde Dragon Company Award

With more than 30 years of professional experience in the production of liquid level gauge products, including "magnetic vacuum level gauge", "oil automatic dehydrator", "flame monitoring system", including more than a dozen technical patents and product patents.

2024-10-24

How to improve the level of the manufacturing process of the product?

Want to improve the liquid level gauge manufacturing process? From optimizing the production process, material selection to technological innovation, comprehensive improvement can meet the market challenges!

2024-09-24

Research and Development Process and Technological Breakthrough of Liquid Level Meter Products

This paper deeply discusses the research and development process and technological breakthrough of vacuum type magnetic level gauge, and reveals the importance of this product in industrial applications and the future development direction. Come and learn about this exciting technological evolution!

2024-09-14